Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.

CAD CART (0)
  • Cart is empty
  • dpd-dpg-rightquarter-hr

    DP16GM

    (6)

    Whole House Packaged Gas/Electric

    • Heavy-duty stainless-steel heat exchanger
    • High-efficiency two-stage scroll compressor with factory-installed sound blanket
    • Variable-speed ECM indoor blower motor
    • Copper tube/aluminum fin evaporator coil (5 Ton)
    • All-aluminum evaporator coil (2-4 Ton)
    • Two-stage gas valve; natural gas with easy conversion to propane
    • Power-assisted combustion
    • All blower operation and all safety circuits complete with self-diagnostics
    • Loss-of-charge protection and high-pressure switch
    • Direct-spark ignition system with microprocessor-based control for the entire ignition sequence
    • For installation in California’s South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the SCAQMD Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
    • AHRI Certified; ETL Listed
    • Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant powder-paint finish
    • Aluminum foil-facing internal insulation reinforced with fiberglass scrim
    • Compressor sound blanket
    • Compressor grommets for vibration isolation
    • All models fit in a standard-size pick-up truck
    • Convenient access panels
    • Bottom 2" high base rails for easier handling
    • When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

  • dpd-dpg-rightquarter-hr

    DP14GM

    (15)

    Whole House Packaged Gas/Electric

    • Heavy-duty stainless-steel heat exchanger
    • Energy-efficient compressor
    • All-aluminum evaporator coil
    • Aluminum tube/aluminum fin coil
    • Flowrater expansion device on 2- to 4-ton units TXV expansion device on 5-ton units
    • Multi-speed ECM blower motor
    • Redundant gas valve with easy conversion to propane
    • Power-assisted combustion
    • Direct spark ignition system includes a microprocessor-based control for the entire ignition sequence, all blower operation, and all safety circuits complete with self-diagnostics
    • For installation in California’s South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the SCAQMD Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
    • AHRI Certified; ETL Listed
    • Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant powder-paint finish
    • Horizontal or downflow application
    • Aluminum foil-facing internal insulation reinforced with fiberglass scrim
    • Compressor sound blanket
    • Convenient access panels
    • One roof curb fits all units
    • Fully insulated cabinet
    • Bottom, 2" high base rails for easier handling
    • One footprint; two heights
    • When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

  • dpd-dpg-rightquarter-hr

    DP14DM

    (5)

    Whole House Packaged Dual-Fuel Unit

    • Combines cooling with heat pump and gas heating for optimal year-long performance
    • High-efficiency scroll compressor
    • Heavy-duty stainless-steel tubular heat exchanger
    • Multi-Speed ECM indoor blower motor
    • All-aluminum evaporator coil
    • Copper tube / aluminum fin coil
    • Two-stage gas valve; natural gas with easy conversion to propane with accessory kit
    • Power-assisted combustion
    • Loss-of-charge protection
    • AHRI Certified; ETL Listed
    • Direct spark ignition system with a microprocessorbased control for the entire ignition sequence
    • All blower operation and all safety circuits complete with self-diagnostics
    • For installation in California’s South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the SCAQMD Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
    • Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant powder-paint finish
    • Compressor sound blanket
    • Louvered metal panel condenser coil protection
    • Aluminum foil-facing internal insulation reinforced with fiberglass scrim
    • Horizontal or downflow application
    • Convenient access panels
    • One roof curb fits all units
    • Bottom, 2” high base rails for easy handling
    • All models fit a standard-size pick-up truck
    • When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.