Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.
CAD CART (0)
▾
DFC Commercial
Cooling Only
Light Commercial
Unit of Measure
Items |
DFC0361D000001S 3 Ton AC Direct Drive Single Phase 208-230V |
DFC0363D0000001S 3 Ton AC Direct Drive 3 Phase 208-230V |
DFC0364D0000001S 3 Ton AC Direct Drive 3 Phase 460V |
DFC0367D0000001S 3 Ton AC Direct Drive 3 Phase 575V |
DFC0481D000001S 4 Ton AC Direct Drive Single Phase 208-230V |
|||||
Type | N/A Light Commercial Packaged Air Conditioner | |||||||||
Cooling Capacity | N/A 35000 Btu/h3 T | N/A 35000 Btu/h3 T | N/A 35000 Btu/h3 T | N/A 35000 Btu/h3 T | N/A 47000 Btu/h4 T | |||||
IEER | N/A | |||||||||
System Performance SEER | N/A | N/A 14.0 | N/A 14.0 | N/A 14.0 | N/A | |||||
System Performance EER | N/A | N/A 11.5 | N/A 11.5 | N/A 11.5 | N/A | |||||
System Performance SEER2 | N/A 13.4 | |||||||||
System Performance EER2 | N/A 11.0 | |||||||||
AHRI Reference # | N/A 208120664 | N/A 208120661 | N/A 208120662 | N/A 208120663 | N/A 208120672 | |||||
Sound Level | N/A 73 dB | N/A 73 dB | N/A 73 dB | N/A 73 dB | N/A 78.4 dB | |||||
Evaporator Motor Type | N/A Direct Drive | |||||||||
External Static Pressure (ESP) | N/A Standard | |||||||||
Evaporator Motor / Coil - Wheel Dia. x Width | N/A 12 x 11 in | |||||||||
Evaporator Motor / Coil - Indoor Nominal CFM | N/A 1160 | N/A 1160 | N/A 1160 | N/A 1160 | N/A 1570 | |||||
Evaporator Motor - RPM | N/A 1200/VAR | N/A 1200/VAR | N/A 300-1500 | N/A 300-1500 | N/A 1200/VAR | |||||
Evaporator Motor Horsepower | N/A 3/4 hp | N/A 3/4 hp | N/A 1.2 hp | N/A 1.2 hp | N/A 1.0 hp | |||||
Evaporator Motor / Coil - Filter Size | N/A 20 x 25 x 2 (2) in | |||||||||
Evaporator Motor / Coil - Drain Size (NPT) | N/A 3/4 in | |||||||||
Evaporator Motor / Coil - R-410A Refrigerant Charge | N/A 52 oz | N/A 52 oz | N/A 52 oz | N/A 52 oz | N/A 79 oz | |||||
Evaporator Coil Face Area | N/A 6.41 ft² | |||||||||
Evaporator Coil - Rows Deep | N/A 2 | N/A 2 | N/A 2 | N/A 2 | N/A 3 | |||||
Evaporator Coil - Fins per Inch | N/A 16 | |||||||||
Quantity of Condenser Fan Motors | N/A 1 | |||||||||
Condenser Fan - RPM (High/Low stage) | N/A 810 | N/A 810 | N/A 810 | N/A 810 | N/A 1122 | |||||
Condenser Fan - Outdoor Horsepower | N/A 1/6 hp | N/A 1/6 hp | N/A 1/6 hp | N/A 1/6 hp | N/A 1/3 hp | |||||
Condenser Fan Diameter | N/A 22 in | |||||||||
Condenser Fan - No. of Fan Blades | N/A 3 | |||||||||
Condenser Coil Face Area | N/A 12.3 ft² | |||||||||
Condenser Coil - Rows Deep | N/A 1 | |||||||||
Condenser Coil - Fins per Inch | N/A 23 | |||||||||
Compressor Quantity | N/A 1 | |||||||||
Compressor Type | N/A Scroll | |||||||||
Compressor Stage | N/A | |||||||||
Compressor Rated Load Amps | N/A 16.7 A | N/A 10.4 A | N/A 5.8 A | N/A 3.8 A | N/A 19.9 A | |||||
Compressor Locked Rotor Amps | N/A 79 A | N/A 73 A | N/A 38 A | N/A 36.5 A | N/A 109 A | |||||
Voltage | N/A 208 to 230 V | N/A 208 to 230 V | N/A 460 V | N/A 575 V | N/A 208 to 230 V | |||||
Number of Phases | N/A 1 | N/A 3 | N/A 3 | N/A 3 | N/A 1 | |||||
Frequency | N/A 60 Hz | |||||||||
Indoor Blower FLA | N/A 5.7 A | N/A 5.7 A | N/A 2.5 A | N/A 2 A | N/A 6.9 A | |||||
Max External Static | N/A 0.8 inWc | |||||||||
Outdoor Fan FLA | N/A 0.95 A | N/A 0.95 A | N/A 0.48 A | N/A 0.39 A | N/A 2 A | |||||
Min. Circuit Ampacity | N/A 27.5 / 27.5 A | N/A 19.7 / 19.7 A | N/A 10.2 A | N/A 7.12 A | N/A 33.7 / 33.7 A | |||||
Max. Overcurrent Protection | N/A 40 / 40 A | N/A 30 / 30 A | N/A 15 A | N/A 15 A | N/A 50 / 50 A | |||||
Power Supply Conduit Hole Diameter | N/A 1.125 in | |||||||||
Low-Voltage Conduit Hole Diameter | N/A 0.5 in | |||||||||
Depth | N/A 74 in | |||||||||
Width | N/A 48-5/16 in | |||||||||
Height | N/A 39-7/8 in | |||||||||
Operating Weight | N/A 484 lb | N/A 482 lb | N/A 490 lb | N/A 490 lb | N/A 507 lb | |||||
Shipping Weight | N/A 554 lb | N/A 552 lb | N/A 560 lb | N/A 560 lb | N/A 577 lb | |||||
Features |
N/A
Installation Daikin Packaged units are designed with an easier and faster installation in mind for both new construction and retrofit. Our packaged rooftop units are built to be a direct replacement for most rooftop units on the field without the need of a curb adapter, to be able to replace the unit in a shorter time and at a lower cost. Cabinet Construction Daikin packaged rooftop units are made with high quality galvanized steel with a powder-paint finish to provide higher corrosion resistance. Compressor High performance, low noise scroll compressors, adjust the speed to match the required total cooling and heating load for efficient part load control. Supply Fan The direct-drive with airfoil single width, single inlet (SWSI) Class II construction supply fan with aluminum fan +blades provides efficient and quiet operation at wide ranging static pressure and air flow requirements. Coils All units use large face area outdoor coils. These coils are constructed with seamless copper tubes, mechanically bonded into aluminum plate-type fins with full drawn collars to completely cover the tubes for high operating efficiencies. Controls and Wiring Packaged rooftop units come equipped with a well-organized, large, easy to use weather proof internal control box with easy access, for a better user experience. Filtration Unit provides a draw-through filter section as standard for better air quality and longer lasting component maintenance. Heating Section Wide ranging of electric heat selections effectively handle most comfort heating demand from morning warm-up control to full heat. Electric Heat ETL approved electric heat is factory assembled, installed and tested. Electrical Units are completely wired and tested at the factory to provide faster commissioning and start-up. |
|||||||||
|
Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.