VRV IV X Heat Recovery Outdoor Units – REYQ_XB**A Series
VRV Heat Recovery Outdoor Units
-
Packed with advanced technology, VRV IV X is the industry's first 3-phase variable refrigerant flow system with dual-fuel capability. The new series is equipped with features to optimize initial capital required on phased installations and provides ease of service and maintenance.
- VRV with Variable Refrigerant Temperature (VRT) technology
- Industry’s first 3-phase variable refrigerant flow system to integrate with communicating gas furnaces
- Design flexibility to enlarge system from single to dual module or dual to triple module without change to installed main pipe sizes – refer to the VRV IV X engineering manual for details
- Capacity range from 6 to 38 tons
- 208-230V / 3ph / 60Hz (REYQ_XBTJA)
- 460V / 3ph / 60Hz (REYQ_XBYDA)
- 575V / 3ph / 60Hz (REYQ_XBYCA)
Unit of Measure
Items |
REYQ72XBTJA VRV Heat Recovery Outdoor Units - REYQ_XBTJA Series |
REYQ96XBTJA VRV Heat Recovery Outdoor Units - REYQ_XBTJA Series |
REYQ120XBTJA VRV Heat Recovery Outdoor Units - REYQ_XBTJA Series |
REYQ144XBTJA VRV Heat Recovery Outdoor Units - REYQ_XBTJA Series |
REYQ168XBTJA VRV Heat Recovery Outdoor Units - REYQ_XBTJA Series |
|||||
Nominal Cooling Capacity | N/A 72000 Btu/h21.1 kW | N/A 96000 Btu/h28.1 kW | N/A 119000 Btu/h35.2 kW | N/A 144000 Btu/h42.2 kW | N/A 160000 Btu/h49.2 kW | |||||
Rated Cooling Capacity | N/A 69000 Btu/h20.2 kW | N/A 92000 Btu/h27.0 kW | N/A 114000 Btu/h33.4 kW | N/A 138000 Btu/h40.4 kW | N/A 150000 Btu/h44.4 kW | |||||
Nominal Heating Capacity | N/A 81000 Btu/h23.7 kW | N/A 108000 Btu/h31.7 kW | N/A 135000 Btu/h39.6 kW | N/A 162000 Btu/h47.5 kW | N/A 188000 Btu/h55.1 kW | |||||
Rated Heating Capacity | N/A 77000 Btu/h22.6 kW | N/A 103000 Btu/h30.2 kW | N/A 129000 Btu/h37.8 kW | N/A 154000 Btu/h45.1 kW | N/A 180000 Btu/h52.8 kW | |||||
Power Supply | N/A 3 phase, 208 / 230 V, 60 Hz | |||||||||
Min/Max Volts | N/A 187/253 V | |||||||||
Maximum Overcurrent Protection | N/A 45 A | N/A 45 A | N/A 50 A | N/A 70 A | N/A 70 A | |||||
Min. Circuit Ampacity | N/A 38.1 A | N/A 38.1 A | N/A 43 A | N/A 58.3 A | N/A 61.9 A | |||||
Compressor Rated Load Amps | N/A 20.8 A | N/A 23.3 A | N/A 28.2 A | N/A 42.6 A | N/A 49.0 A | |||||
Outdoor Fan Motor - Rated Output | N/A 0.8 × 2 kW2.9 × 2 A | |||||||||
Short-Circuit Current Rating | N/A SCCR kA rms, Symmetrical 600 V MAX: 5 | |||||||||
Color | N/A Ivory White (5Y7.5/1) | |||||||||
Heat Exchanger | N/A Cross Fin Coil | |||||||||
Compressor Type | N/A Hermetically sealed scroll type | |||||||||
Compressor Volume | N/A 12.7 m³/h | N/A 17.4 m³/h | N/A 23.4 m³/h | N/A 27.7 m³/h | N/A 33.6 m³/h | |||||
Compressor Number of Revolutions | N/A 3.738 rpm | N/A 5.142 rpm | N/A 6.888 rpm | N/A 5.214 rpm | N/A 6.330 rpm | |||||
Compressor Motor Output x Number of Units | N/A 3.9 x 1 kW | N/A 5.4 x 1 kW | N/A 7.2 x 1 kW | N/A 8.0 x 1 kW | N/A 9.7 x 1 kW | |||||
Compressor Starting Method | N/A Soft Start | |||||||||
Fan Type | N/A Propeller fan | |||||||||
Fan Motor Output | N/A 0.8 x 2 kW | |||||||||
Fan Air Flow Rate | N/A 7283 ft³/min206 m³/min | N/A 7989 ft³/min226 m³/min | N/A 7989 ft³/min226 m³/min | N/A 9480 ft³/min268 m³/min | N/A 9480 ft³/min268 m³/min | |||||
Fan Drive | N/A Direct drive | |||||||||
Height | N/A 66-11/16 in1694 mm | |||||||||
Width | N/A 48-7/8 in1242 mm | |||||||||
Depth | N/A 30-3/16 in767 mm | |||||||||
Pipe Connections - Liquid | N/A 3/8 in9.5 mm | N/A 3/8 in9.5 mm | N/A 1/2 in12.7 mm | N/A 1/2 in12.7 mm | N/A 5/8 in15.9 mm | |||||
Pipe Connections - Suction Gas Pipe | N/A 3/4 in19.1 mm | N/A 7/8 in22.2 mm | N/A 1-1/8 in28.6 mm | N/A 1-1/8 in28.6 mm | N/A 1-1/8 in28.6 mm | |||||
Pipe Connections - High/Low Pressure Gas | N/A 5/8 in15.9 mm | N/A 3/4 in19.1 mm | N/A 3/4 in19.1 mm | N/A 7/8 in22.2 mm | N/A 7/8 in22.2 mm | |||||
Weight | N/A 330 kg727 lb | N/A 330 kg727 lb | N/A 330 kg727 lb | N/A 360 kg793 lb | N/A 360 kg793 lb | |||||
Sound Level | N/A 58 dB | N/A 61 dB | N/A 61 dB | N/A 65 dB | N/A 65 dB | |||||
Sound Power Level (Reference Data) | N/A 79 dB | N/A 80 dB | N/A 80.5 dB | N/A 87 dB | N/A 88 dB | |||||
Safety Devices | N/A High Pressure Switch, Fan Driver Overload Protector, Overcurrent Fuse, Inverter Overload Protector, Leak Detecting Device | |||||||||
Defrost Method | N/A Deicer | |||||||||
Capacity Control | N/A 15 to 100 % | N/A 13 to 100 % | N/A 11 to 100 % | N/A 14 to 100 % | N/A 12 to 100 % | |||||
Refrigerant Name | N/A R410A | |||||||||
Refrigerant Control | N/A Electronic Expansion Valve | |||||||||
Refrigerant Charge | N/A 25.8 lb11.7 kg | |||||||||
Standard Accessories | N/A Installation Manual, Operation Manual, Connection Pipes, Clamps | |||||||||
System Performance Heating COP 17F Ducted | N/A 2.25 | N/A 2.26 | N/A 2.25 | N/A 2.1 | N/A 2.05 | |||||
System Performance Heating COP 17F Non-Ducted | N/A 2.36 | N/A 2.32 | N/A 2.25 | N/A 2.05 | N/A 2.05 | |||||
System Performance Heating COP 47F Ducted | N/A 3.6 | N/A 3.5 | N/A 3.46 | N/A 3.35 | N/A 3.2 | |||||
System Performance Heating COP 47F Non-Ducted | N/A 3.82 | N/A 3.75 | N/A 3.48 | N/A 3.32 | N/A 3.2 | |||||
System Performance EER Ducted | N/A 12.8 | N/A 11.6 | N/A 10.8 | N/A 10.3 | N/A 9.7 | |||||
System Performance EER Non-Ducted | N/A 12.2 | N/A 11.4 | N/A 10.6 | N/A 10.6 | N/A 9.9 | |||||
System Performance IEER Ducted | N/A 18.9 | N/A 18.3 | N/A 17.8 | N/A 17.3 | N/A 16.6 | |||||
System Performance IEER Non-Ducted | N/A 19.4 | N/A 20.4 | N/A 20 | N/A 19 | N/A 18.9 | |||||
|
Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.