Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.

CAD CART (0)
  • Cart is empty
Unit of Measure

Model Type

N/A Wall Mounted Unit

Rated Cooling Capacity

N/A 8800 Btu/h2.57 kW

Min Cooling Capacity

N/A 4400 Btu/h1.30 kW

Max Cooling Capacity

N/A 10200 Btu/h3.00 kW

Rated Heating Capacity

N/A 9400 Btu/h2.75 kW

Min Heating Capacity

N/A 4400 Btu/h1.30 kW

Max Heating Capacity

N/A 13000 Btu/h3.80 kW

System Running Current (Rated, Cooling)

N/A 3.82 A

System Running Current (Rated, Heating)

N/A 3.70 A

System Power Consumption (Rated, Cooling)

N/A 800 W

System Power Consumption (Rated, Heating)

N/A 774 W

Moisture Removal

N/A 0.09 gal/h

Frequency

N/A 60 Hz

Power Supply

N/A 208-230 V/ 60 Hz / 1 Phase

Voltage

N/A 208-230 V

Fan Type

N/A Cross Flow Fan

Fan Drive

N/A Direct

Fan Speed

N/A 3 Steps, Quiet, Auto, Turbo

Fan Motor Type

N/A Direct Current

Fan Motor Output

N/A 22 W

Fan Motor Running Current (Rated)

N/A 0.10 A

Fan Motor Power Consumption (Rated)

N/A 29 W

Operation Sound (H/M/L/SL) – Cooling

N/A 43 / 36 / 29 / 19 dBA

Operation Sound (H/M/L/SL) – Heating

N/A 42 / 35 / 29 / 25 dBA

Airflow Rate (Turbo)

N/A 466 ft³/min

Airflow Rate (H)

N/A 431/402 ft³/min

Airflow Rate (M)

N/A 322 ft³/min

Airflow Rate (L)

N/A 249 ft³/min

Airflow Rate (SL)

N/A 219 ft³/min

Air Filter

N/A Catechin

Air Direction Control

N/A Up, Down, Left, Right

Rated Cooling Conditions

N/A Indoor: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) Outdoor: 95°FDB (35°CDB)

Rated Heating Conditions

N/A Indoor: 70°FDB (21.1°CDB) Outdoor: 47°FDB (8.3°CDB) / 43°FWB(6.1°CWB)

Amount of Additional Charge of Refrigerant

N/A 0.21 oz/ft20 g/m

Weight

N/A 9.2 kg20 lb

Gross Weight

N/A 24.7 lb11.2 kg

Depth

N/A 9-3/16 in234 mm

Width

N/A 30-5/16 in770 mm

Height

N/A 11-1/3 in288 mm

Pipe Connections - Liquid

N/A 1/4 in6.4 mm

Pipe Connections - Gas

N/A 3/8 in9.5 mm

Max. Interunit Height Difference

N/A 32-13/16 ft10 m

Max. Interunit Piping Length

N/A 65-5/8 ft20 m

Packaged Depth

N/A 12-3/8 in314 mm

Packaged Width

N/A 32-3/4 in830 mm

Packaged Height

N/A 13-7/8 in350 mm

System Performance EER2

N/A 11.0 Btu/h/W

System Performance SEER2

N/A 18

System Performance HSPF2

N/A 9.0

System Performance Heating COP2

N/A 12.15

Min. Circuit Ampacity

N/A 12.35 A

Maximum Overcurrent Protection

N/A 15 A

Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.