Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.
- Specifications
- System Efficiency Metrics
- Compressor
- Fan
- Refrigerant
- Dimensions
- Features and Benefits
Power Supply |
N/A 1 phase, 208/230 V, 60 Hz |
Cooling Capacity - Nominal |
N/A 24000 Btu/h7.0 kW |
Cooling Capacity - Rated |
N/A 23000 Btu/h6.7 kW |
Heating Capacity - Nominal |
N/A 27000 Btu/h7.9 kW |
Rated Heating Capacity (at 17°F) - Ducted |
N/A 16800 Btu/h |
Rated Heating Capacity (at 17°F) - Non-Ducted |
N/A 14000 Btu/h |
Rated Heating Capacity (at 17°F) - Mixed |
N/A 15400 Btu/h |
Rated Heating Capacity (at 47°F) - Ducted |
N/A 25000 Btu/h |
Rated Heating Capacity (at 47°F) - Non-Ducted |
N/A 25800 Btu/h |
Rated Heating Capacity (at 47°F) - Mixed |
N/A 25400 Btu/h |
Standard Compliance |
N/A UL |
Casing Color |
N/A Ivory White |
Heat Exchanger |
N/A Cross Fin Coil |
Sound Pressure Level - Cooling |
N/A 58 dBA |
Sound Pressure Level - Heating |
N/A 61 dBA |
Sound Power Level - Cooling |
N/A 75 dB |
Sound Power Level - Heating |
N/A 79 dB |
Safety Devices |
N/A High Pressure Switch, Fan Driver Overload Protector, Inverter Overload Protector, Fusible Plug, Fuse |
Defrost Method |
N/A Reverse Cycle Defrosting |
Capacity Control |
N/A 14 to 100 % |
Standard Accessories |
N/A Installation Manual, Operation Manual, Drain Socket, Clamps |
Weight |
N/A 78 kg172 lb |
System Performance EER2 Ducted |
N/A 11.2 |
System Performance EER Ducted |
N/A 11.2 |
System Performance EER2 Non-Ducted |
N/A 14.5 |
System Performance EER Non-Ducted |
N/A 14.3 |
System Performance EER Mixed |
N/A 12.75 |
System Performance SEER2 Ducted |
N/A 15.9 |
System Performance SEER Ducted |
N/A 15.9 |
System Performance SEER2 Non-Ducted |
N/A 23 |
System Performance SEER Non-Ducted |
N/A 18 |
System Performance SEER Mixed |
N/A 16.95 |
System Performance HSPF2 Ducted |
N/A 8.2 |
System Performance HSPF Ducted |
N/A 8.2 |
System Performance HSPF2 Non-Ducted |
N/A 9.6 |
System Performance HSPF Non-Ducted |
N/A 8.8 |
System Performance HSPF Mixed |
N/A 8.5 |
COP (at 17°F) - Ducted |
N/A 2.45 |
COP (at 17°F) - Non-Ducted |
N/A 2.79 |
COP (at 17°F) - Mixed |
N/A 2.62 |
COP (at 47°F) - Ducted |
N/A 3.35 |
COP (at 47°F) - Non-Ducted |
N/A 4.5 |
COP (at 47°F) - Mixed |
N/A 4.00 |
Type |
N/A Hermetically Sealed Swing Type |
Motor Output |
N/A 1.9 kW |
Starting Method |
N/A Soft Start |
Type |
N/A Propeller Fan |
Motor Output |
N/A 0.200 kW |
Airflow Rate |
N/A 2682 scfm76 m³/min |
Drive |
N/A Direct Drive |
Refrigerant Name |
N/A R410A |
Charge |
N/A 2.9 kg6.4 lb |
Control |
N/A Electronic Expansion Valve |
Depth |
N/A 12 5/8 in320 mm |
Width |
N/A 37 in940 mm |
Height |
N/A 39 in990 mm |
Pipe Connections - Liquid |
N/A 3/8 in9.5 mm |
Pipe Connections - Gas |
N/A 5/8 in15.9 mm |
Maximum allowable length between OD and ID unit - Actual Piping Length |
N/A 100 ft30.5 m |
Maximum allowable length between OD and ID unit -Equivalent Piping Length |
N/A 125 ft38.1 m |
Maximum allowable length between OD and ID unit - Total Piping Length |
N/A 328 ft100 m |
Maximum allowable height difference between OD and ID units - Difference in Height |
N/A 98 ft30 m |
Maximum allowable height difference between ID and ID units - Difference in Height |
N/A 33 ft10 m |
N/A
Re-inventing residential air-conditioning by breaking technological barriers, the new Residential VRV brings inverter driven VRV to solve some of the age-old single-family HVAC challenges.
|
Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.