Items |
DFG0361D100001F 3 Ton Gas/Electric Direct Drive Single Phase 208-230V |
DFG0361D600001F 3 Ton Gas/Electric Direct Drive Single Phase 208-230V |
DFG0361D800001F 3 Ton Gas/Electric Direct Drive Single Phase 208-230V |
DFG0361DH00001S 3 Ton Gas/Electric Direct Drive Single Phase 208-230V |
DFG0361DL00001S 3 Ton Gas/Electric Direct Drive Single Phase 208-230V |
|||||
Type | N/A Light Commercial Packaged Gas/Electric | |||||||||
Cooling Capacity | N/A 35000 Btu/h3 T | |||||||||
IEER | N/A | |||||||||
SEER | N/A | |||||||||
EER | N/A | |||||||||
SEER2 | N/A 13.4 | |||||||||
EER2 | N/A 11.0 | |||||||||
AHRI Reference # | N/A 208120660 | |||||||||
Sound Level | N/A 73 dB | |||||||||
Heating Capacity | N/A 100000 Btu/h | N/A 60000 Btu/h | N/A 80000 Btu/h | N/A 90000 Btu/h | N/A 45000 Btu/h | |||||
Heat Range | N/A High | N/A Low | N/A Medium | N/A High | N/A Low | |||||
No. of Burners | N/A 5 | N/A 3 | N/A 4 | N/A 4 | N/A 2 | |||||
High Stage Input | N/A 100.0 Btu/h | N/A 60.0 Btu/h | N/A 80.0 Btu/h | N/A 90.0 Btu/h | N/A 45.0 Btu/h | |||||
High Stage Output | N/A 81.0 Btu/h | N/A 48.6 Btu/h | N/A 64.8 Btu/h | N/A 72.9 Btu/h | N/A 36.5 Btu/h | |||||
Low Stage Input | N/A | |||||||||
Low Stage Output | N/A | |||||||||
Thermal Efficiency | N/A | |||||||||
Annual Fuel Utilization Efficiency (AFUE) | N/A 81 | |||||||||
High Stage Temperature Rise Range | N/A 40 to 70 ºF | N/A 30 to 60 ºF | N/A 30 to 60 ºF | N/A 25 to 55 ºF | N/A 15 to 45 ºF | |||||
Low Stage Temperature Rise Range | N/A | |||||||||
Evaporator Motor Type | N/A Direct Drive | |||||||||
External Static Pressure (ESP) | N/A Standard | |||||||||
Evaporator Motor / Coil - Wheel Dia. x Width | N/A 12 x 11 in | |||||||||
Evaporator Motor / Coil - Indoor Nominal CFM | N/A 1160 | |||||||||
Evaporator Motor - RPM | N/A 1200/VAR | |||||||||
Evaporator Motor Horsepower | N/A 3/4 hp | |||||||||
Evaporator Motor / Coil - Filter Size | N/A 20 x 25 x 2 (2) in | |||||||||
Evaporator Motor / Coil - Drain Size (NPT) | N/A 3/4 in | |||||||||
Evaporator Motor / Coil - R-410A Refrigerant Charge | N/A 52 oz | |||||||||
Evaporator Coil Face Area | N/A 6.41 ft² | |||||||||
Evaporator Coil - Rows Deep | N/A 2 | |||||||||
Evaporator Coil - Fins per Inch | N/A 16 | |||||||||
Quantity of Condenser Fan Motors | N/A 1 | |||||||||
Condenser Fan - RPM (High/Low stage) | N/A 810 | |||||||||
Condenser Fan - Outdoor Horsepower | N/A 1/6 hp | |||||||||
Condenser Fan Diameter | N/A 22 in | |||||||||
Condenser Fan - No. of Fan Blades | N/A 3 | |||||||||
Condenser Coil Face Area | N/A 12.3 ft² | |||||||||
Condenser Coil - Rows Deep | N/A 1 | |||||||||
Condenser Coil - Fins per Inch | N/A 23 | |||||||||
Compressor Quantity | N/A 1 | |||||||||
Compressor Type | N/A Scroll | |||||||||
Compressor Stage | N/A 1 | |||||||||
Compressor Rated Load Amps | N/A 16.7 A | |||||||||
Compressor Locked Rotor Amps | N/A 79 A | |||||||||
Voltage | N/A 208 to 230 V | |||||||||
Number of Phases | N/A 1 | |||||||||
Frequency | N/A 60 Hz | |||||||||
Indoor Blower FLA | N/A 5.7 A | |||||||||
Max External Static | N/A 0.8 inWc | |||||||||
Outdoor Fan FLA | N/A 0.95 A | |||||||||
Min. Circuit Ampacity | N/A 27.5/27.5 A | |||||||||
Max. Overcurrent Protection | N/A 40/40 A | |||||||||
Power Supply Conduit Hole Diameter | N/A 1.125 in | |||||||||
Low-Voltage Conduit Hole Diameter | N/A 0.5 in | |||||||||
Operating Weight | N/A 519 lb | N/A 506 lb | N/A 512 lb | N/A 512 lb | N/A 500 lb | |||||
Shipping Weight | N/A 589 lb | N/A 576 lb | N/A 582 lb | N/A 582 lb | N/A 570 lb | |||||
Depth | N/A 74 in | |||||||||
Width | N/A 48-5/16 in | |||||||||
Height | N/A 39-7/8 in | |||||||||
|