Items |
DC80VC0603BX DC80VC - ComfortNet™-Compatible Two-Stage, Variable-Speed Gas Furnace 80% AFUE |
DC80VC0803BX DC80VC - ComfortNet™-Compatible Two-Stage, Variable-Speed Gas Furnace 80% AFUE |
DC80VC0805CX DC80VC - ComfortNet™-Compatible Two-Stage, Variable-Speed Gas Furnace 80% AFUE |
DC80VC1005CX DC80VC - ComfortNet™-Compatible Two-Stage, Variable-Speed Gas Furnace 80% AFUE |
||||
High-Fire Input | N/A 60000 Btu/h | N/A 80000 Btu/h | N/A 80000 Btu/h | N/A 100000 Btu/h | ||||
High-Fire Output | N/A 48000 Btu/h | N/A 64000 Btu/h | N/A 64000 Btu/h | N/A 80000 Btu/h | ||||
Low-Fire Steady-State Input | N/A 42000 Btu/h | N/A 56000 Btu/h | N/A 56000 Btu/h | N/A 70000 Btu/h | ||||
Low-Fire Steady-State Output | N/A 33600 Btu/h | N/A 44800 Btu/h | N/A 44800 Btu/h | N/A 56000 Btu/h | ||||
Annualized Fuel Utilization Efficiency | N/A 80 % | |||||||
Available AC | N/A 1.5 to 3.0 A | N/A 1.5 to 3.0 A | N/A 2.0 to 5.0 A | N/A 2.0 to 5.0 A | ||||
Temperature Rise Range | N/A 25 - 55ºF 40 - 70ºF | N/A 30 - 60ºF | N/A 25 - 55ºF 30 - 60ºF | N/A 20 - 50ºF 25 - 55ºF | ||||
Size (D x W) | N/A 10 x 8 | N/A 10 x 8 | N/A 10 x 10 | N/A 10 x 10 | ||||
Circulator Blower - Horsepower | N/A 1/2 hp | N/A 1/2 hp | N/A 3/4 hp | N/A 3/4 hp | ||||
Circulator Blower - Speed | N/A Variable | |||||||
Vent Diameter | N/A 4 in | |||||||
No. of Burners | N/A 3 | N/A 4 | N/A 4 | N/A 5 | ||||
Min. Circuit Ampacity | N/A 7.75 A | N/A 7.75 A | N/A 10.6 A | N/A 10.6 A | ||||
Max. Overcurrent Device | N/A 15 A | |||||||
Depth | N/A 28 1/2 in | |||||||
Width | N/A 17 1/2 in | N/A 17 1/2 in | N/A 21 in | N/A 21 in | ||||
Height | N/A 33-1/2 in | |||||||