Items |
DC92SS0402BN DC92SS - Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE |
DC92SS0603BN DC92SS - Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE |
DC92SS0804CN DC92SS - Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE |
DC92SS1005CN DC92SS - Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE |
||||
High-Fire Input | N/A 40000 Btu/h | N/A 60000 Btu/h | N/A 80000 Btu/h | N/A 100000 Btu/h | ||||
High-Fire Output | N/A 36800 Btu/h | N/A 55200 Btu/h | N/A 73600 Btu/h | N/A 92000 Btu/h | ||||
Annualized Fuel Utilization Efficiency | N/A 92 % | |||||||
Temperature Rise Range | N/A 30 - 60ºF | N/A 35 - 65ºF | N/A 35 - 65ºF | N/A 35 - 65ºF | ||||
Vent Diameter | N/A 2 to 3 in | |||||||
No. of Burners | N/A 2 | N/A 3 | N/A 4 | N/A 5 | ||||
Available AC | N/A 1.5 to 3.0 A | N/A 1.5 to 3.0 A | N/A 2.5 to 4 A | N/A 2.5 to 4 A | ||||
Size (D x W) | N/A 10 x 8 | N/A 10 x 8 | N/A 10 x 10 | N/A 11 x 10 | ||||
Circulator Blower - Horsepower | N/A 1/3 hp | N/A 1/3 hp | N/A 1/2 hp | N/A 3/4 hp | ||||
Circulator Blower - Speed | N/A 4 | |||||||
Circulator Blower - RPM | N/A 1075 | |||||||
Min. Circuit Ampacity | N/A 9.6 A | N/A 9.6 A | N/A 11.7 A | N/A 13.7 A | ||||
Max. Overcurrent Device | N/A 15 A | |||||||
Depth | N/A 29 in | |||||||
Width | N/A 17 1/2 in | N/A 17 1/2 in | N/A 21 in | N/A 21 in | ||||
Height | N/A 34 1/2 in | |||||||
Shipping Weight | N/A 109 lb | N/A 112 lb | N/A 137 lb | N/A 140 lb | ||||
|