Print Back
  • Heavy-duty stainless-steel heat exchanger
  • Energy-efficient compressor
  • All-aluminum evaporator coil
  • Flowrater expansion device on 2- to 4-ton units TXV expansion device on 5-ton units
  • Multi-speed ECM blower motor
  • Redundant gas valve with easy conversion to propane
  • Power-assisted combustion
  • Direct spark ignition system includes a microprocessor-based control for the entire ignition sequence, all blower operation, and all safety circuits complete with self-diagnostics
  • This furnace does not comply with the SCAQMD Rule 1111 nor the SJVAPCD Rule 4905 14 ng/J NOx emission limit and therefore is not eligible for installation in California’s South Coast Air Quality Management District (SCAQMD) nor the San Joaquin Valley Air Pollution Control District (SJVAPCD).
  • All models comply with California Low NOx standards.
  • AHRI Certified; ETL Listed
Unit of Measure

Specifications

Nominal Capacity

N/A 2.5 T

Cooling Capacity

N/A 28600 Btu/h

Sensible Cooling Capacity

N/A 23080 Btu/h

System Performance SEER2

N/A 13.4

System Performance EER2

N/A 10.6

AHRI Reference

N/A 209319525

Heating Capacity Input

N/A 40000 Btu/h

Heating Capacity Output

N/A 32400 Btu/h

Heating Capacity Low-Fire Output

N/A 32400 Btu/h

Sound Level

N/A 78 dB

Annualized Fuel Utilization Efficiency (AFUE)

N/A 81 %

Temperature Rise Range

N/A 25 - 55 °F

No. of Burners

N/A 2

Orifice Size Natural

N/A 45 in

Orifice Size Propan

N/A 1.25 mm

Voltage

N/A 208 to 230 V

Phase

N/A 1

Frequency

N/A 60 Hz

Indoor Blower - Full Load Amps (FLA)

N/A 3.8 A

Outdoor Fan - Full Load Amps (FLA)

N/A 1.4 A

Outdoor Fan - Rated Load Amps (RLA)

N/A 3.2 A

Total Unit Amps

N/A 19.4 A

Min. Circuit Ampacity

N/A 22.8 A

Max. Overcurrent Protection

N/A 35 A

Shipping Weight

N/A 438 lb

Operating Weight

N/A 415 lb

Evaporator Motor

Type

N/A ECM

Wheel (D x W)

N/A 10 x 8

Evaporator Motor Cooling

N/A 1000 ft³/min

Indoor Nominal

N/A T4

Motor Amps (Cooling)

N/A 3.9 A

Horsepower

N/A 1/2 hp

RPM

N/A 1050

Evaporator Coil

Face Area

N/A 4.3 ft²

Rows Deep

N/A 3

Fins per Inch

N/A 14

Piston Size (Cooling)

N/A 0.062

Filter Size

N/A 3.4 ft²

Drain Size (NPT)

N/A 3/4 in

Refrigerant Charge

N/A 78 oz

Condenser Fan / Coil

Horsepower

N/A 1/4 hp

RPM

N/A 815

Fan Diameter

N/A 22 in

Fan Blades

N/A 3

Outdoor Nominal

N/A 3050 ft³/min

Face Area

N/A 12.3 ft²

Rows Deep

N/A 1

Fins per Inch

N/A 24

Compressor

Quantity

N/A 1

Type

N/A Scroll

Stage

N/A Single

Rated Load Amps (RLA)

N/A 14.1 A

Locked Rotor Amps (LRA)

N/A 73.0 A

Dimensions

Entrance Size Power Supply

N/A 1 1/8 in

Entrance Size Control Voltage

N/A 7/8 in

Depth

N/A 47 in

Width

N/A 51 in

Height

N/A 34 3/4 in

Features

N/A

Standard Features

  • Heavy-duty stainless-steel heat exchanger
  • Energy-efficient compressor
  • All-aluminum evaporator coil
  • Flowrater expansion device on 2- to 4-ton units TXV expansion device on 5-ton units
  • Multi-speed ECM blower motor
  • Redundant gas valve with easy conversion to propane
  • Power-assisted combustion
  • Direct spark ignition system includes a microprocessor-based control for the entire ignition sequence, all blower operation, and all safety circuits complete with self-diagnostics
  • This furnace does not comply with the SCAQMD Rule 1111 nor the SJVAPCD Rule 4905 14 ng/J NOx emission limit and therefore is not eligible for installation in California’s South Coast Air Quality Management District (SCAQMD) nor the San Joaquin Valley Air Pollution Control District (SJVAPCD).
  • All models comply with California Low NOx standards
  • AHRI Certified; ETL Listed

Cabinet Features

  • Fully insulated cabinet heavy-guage , zinc coated steel cabiinet with UV- resistant powder- paint finish
  • Aluminum foil-facing internal insulation reinforced with fiberglass scrim
  • Convenient access panels Compressor access panels
  • One roof curb fits all units
  • Horizontal or downflow application
  • Bottom, 2” high base rails for easier handling
  • When properly anchored, meets 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)