VRV IV-S brings the technology of VRV, including Variable Refrigerant Temperature (VRT) technology, to smaller residential and light commercial applications.
Model Type |
N/A Heat Pump Unit |
Heat Exchanger Type |
N/A Cross Fin Coil |
Color |
N/A Ivory White |
Voltage |
N/A 208/230 V |
Phase |
N/A 1 |
Frequency |
N/A 60 Hz |
Cooling Capacity |
N/A 45500 Btu/h13.3 kW |
Nominal Heating Capacity |
N/A 52000 Btu/h15.4 kW |
Rated Heating Capacity (at 17°F) - Ducted |
N/A 30200 Btu/h |
Rated Heating Capacity (at 17°F) - Non-Ducted |
N/A 32200 Btu/h |
Rated Heating Capacity (at 17°F) - Mixed |
N/A 31200 Btu/h |
Rated Heating Capacity (at 47°F) - Ducted |
N/A 46000 Btu/h |
Rated Heating Capacity (at 47°F) - Non-Ducted |
N/A 49500 Btu/h |
Rated Heating Capacity (at 47°F) - Mixed |
N/A 47750 Btu/h |
Standard Compliance |
N/A UL |
Compressor Type |
N/A Hermetically Sealed Swing Type |
Airflow Rate |
N/A 2682 ft³/min |
Safety Devices |
N/A High Pressure Switch, Fan Driver Overload Protector, Inverter Overload Protector, Fusible Plug, Fuse |
Weight |
N/A 80 kg176 lb |
System Performance EER2 Ducted |
N/A 7.9 |
System Performance EER Ducted |
N/A 7.9 |
System Performance EER2 Non-Ducted |
N/A 10.3 |
System Performance EER Non-Ducted |
N/A 10.3 |
System Performance EER Mixed |
N/A 9.1 |
System Performance SEER2 Ducted |
N/A 14.6 |
System Performance SEER Ducted |
N/A 14.6 |
System Performance SEER2 Non-Ducted |
N/A 20 |
System Performance SEER Non-Ducted |
N/A 18.6 |
System Performance SEER Mixed |
N/A 16.6 |
System Performance HSPF2 Ducted |
N/A 8.3 |
System Performance HSPF Ducted |
N/A 8.3 |
System Performance HSPF2 Non-Ducted |
N/A 9.5 |
System Performance HSPF Non-Ducted |
N/A 8.5 |
System Performance HSPF Mixed |
N/A 8.4 |
COP (at 17°F) - Ducted |
N/A 2.7 |
COP (at 17°F) - Non-Ducted |
N/A 3 |
COP (at 17°F) - Mixed |
N/A 2.9 |
COP (at 47°F) - Ducted |
N/A 3.36 |
COP (at 47°F) - Non-Ducted |
N/A 4.0 |
COP (at 47°F) - Mixed |
N/A 3.68 |
Height |
N/A 39 in990 mm |
Width |
N/A 37 in940 mm |
Depth |
N/A 12 5/8 in320 mm |
Pipe Connections - Liquid |
N/A 3/8 in9.5 mm |
Pipe Connections - Gas |
N/A 5/8 in15.9 mm |
Clearance Front Depth |
N/A 20 in |
Clearance Top Depth |
N/A 40 in |
Liquid Pipe Horizontal Offset |
N/A 1.4375 in |
Liquid Pipe Vertical Offset |
N/A 4.4375 in |
Gas Pipe Height |
N/A 18.1875 in |
Liquid Pipe Height |
N/A 18.5625 in |
Gas Pipe Horizontal Offset |
N/A 2.5625 in |
Gas Pipe Vertical Offset |
N/A 1.375 in |
Pipe Length |
N/A 0.5 in |
Maximum allowable length between OD and ID unit - Actual Piping Length |
N/A 230 ft70 m |
Maximum allowable length between OD and ID unit -Equivalent Piping Length |
N/A 295 ft90 m |
Maximum allowable length between OD and ID unit - Total Piping Length |
N/A 984 ft300 m |
Maximum allowable length after branch - Actual Piping Length |
N/A 131 ft40 m |
Maximum allowable height difference between OD and ID units - Difference in Height |
N/A 98 ft30 m |
Maximum allowable height difference between ID and ID units - Difference in Height |
N/A 49 ft15 m |
Heating Capacity Note |
N/A Indoor temp.: 70 ºFDB (21.1 ºCDB) / outdoor temp.: 47 ºFDB (8.3 ºCDB), 43 ºFWB (6.1 ºCWB) / Equivalent piping length: 25 ft (7.6 m), level difference: 0. |
Cooling Capacity Note |
N/A Indoor temp.: 80 ºFDB (26.7 ºCDB), 67 ºFWB (19.4 ºCWB) / outdoor temp.: 95 ºFDB (35.0 ºCDB) / Equivalent piping length: 25 ft (7.6 m), level difference: 0. |