Power Supply |
N/A 1 phase, 208/230 V, 60 Hz |
Cooling Capacity - Nominal |
N/A 36000 Btu/h10.6 kW |
Cooling Capacity - Rated |
N/A 34200 Btu/h10.0 kW |
Heating Capacity - Nominal |
N/A 40000 Btu/h11.7 kW |
Rated Heating Capacity (at 17°F) - Ducted |
N/A 24600 Btu/h |
Rated Heating Capacity (at 17°F) - Non-Ducted |
N/A 23600 Btu/h |
Rated Heating Capacity (at 17°F) - Mixed |
N/A 24100 Btu/h |
Rated Heating Capacity (at 47°F) - Ducted |
N/A 37000 Btu/h |
Rated Heating Capacity (at 47°F) - Non-Ducted |
N/A 37000 Btu/h |
Rated Heating Capacity (at 47°F) - Mixed |
N/A 37000 Btu/h |
Standard Compliance |
N/A UL |
Casing Color |
N/A Ivory White |
Heat Exchanger |
N/A Cross Fin Coil |
Sound Pressure Level - Cooling |
N/A 58 dBA |
Sound Pressure Level - Heating |
N/A 61 dBA |
Sound Power Level - Cooling |
N/A 75 dB |
Sound Power Level - Heating |
N/A 79 dB |
Safety Devices |
N/A High Pressure Switch, Fan Driver Overload Protector, Inverter Overload Protector, Fusible Plug, Fuse |
Defrost Method |
N/A Reverse Cycle Defrosting |
Capacity Control |
N/A 14 to 100 % |
Standard Accessories |
N/A Installation Manual, Operation Manual, Drain Socket, Clamps |
Weight |
N/A 78 kg172 lb |
System Performance EER2 Ducted |
N/A 9.2 |
System Performance EER Ducted |
N/A 9.2 |
System Performance EER2 Non-Ducted |
N/A 12 |
System Performance EER Non-Ducted |
N/A 12 |
System Performance EER Mixed |
N/A 10.6 |
System Performance SEER2 Ducted |
N/A 15.3 |
System Performance SEER Ducted |
N/A 15.3 |
System Performance SEER2 Non-Ducted |
N/A 23 |
System Performance SEER Non-Ducted |
N/A 18.2 |
System Performance SEER Mixed |
N/A 16.75 |
System Performance HSPF2 Ducted |
N/A 8.5 |
System Performance HSPF Ducted |
N/A 8.5 |
System Performance HSPF2 Non-Ducted |
N/A 9.6 |
System Performance HSPF Non-Ducted |
N/A 9 |
System Performance HSPF Mixed |
N/A 8.75 |
COP (at 17°F) - Ducted |
N/A 2.5 |
COP (at 17°F) - Non-Ducted |
N/A 3 |
COP (at 17°F) - Mixed |
N/A 2.75 |
COP (at 47°F) - Ducted |
N/A 3.30 |
COP (at 47°F) - Non-Ducted |
N/A 4.1 |
COP (at 47°F) - Mixed |
N/A 3.70 |
Type |
N/A Hermetically Sealed Swing Type |
Motor Output |
N/A 1.9 kW |
Starting Method |
N/A Soft Start |
Type |
N/A Propeller Fan |
Motor Output |
N/A 0.200 kW |
Airflow Rate |
N/A 2682 scfm76 m³/min |
Drive |
N/A Direct Drive |
Refrigerant Name |
N/A R410A |
Charge |
N/A 2.9 kg6.4 lb |
Control |
N/A Electronic Expansion Valve |
Depth |
N/A 12 5/8 in320 mm |
Width |
N/A 37 in940 mm |
Height |
N/A 39 in990 mm |
Pipe Connections - Liquid |
N/A 3/8 in9.5 mm |
Pipe Connections - Gas |
N/A 5/8 in15.9 mm |
Maximum allowable length between OD and ID unit - Actual Piping Length |
N/A 164 ft50 m |
Maximum allowable length between OD and ID unit -Equivalent Piping Length |
N/A 213 ft65 m |
Maximum allowable length between OD and ID unit - Total Piping Length |
N/A 820 ft250 m |
Maximum allowable length after branch - Actual Piping Length |
N/A 131 ft40 m |
Maximum allowable height difference between OD and ID units - Difference in Height |
N/A 98 ft30 m |
Maximum allowable height difference between ID and ID units - Difference in Height |
N/A 33 ft10 m |
N/A