Print Back
4-ton Residential VRV LIFE
Unit of Measure

Specifications

Power Supply

N/A 1 phase, 208/230 V, 60 Hz

Cooling Capacity - Nominal

N/A 48000 Btu/h14.1 kW

Cooling Capacity - Rated

N/A 45500 Btu/h13.3 kW

Heating Capacity - Nominal

N/A 52000 Btu/h15.2 kW

Rated Heating Capacity (at 17°F) - Ducted

N/A 30200 Btu/h

Rated Heating Capacity (at 17°F) - Non-Ducted

N/A 32200 Btu/h

Rated Heating Capacity (at 17°F) - Mixed

N/A 31200 Btu/h

Rated Heating Capacity (at 47°F) - Ducted

N/A 46000 Btu/h

Rated Heating Capacity (at 47°F) - Non-Ducted

N/A 49500 Btu/h

Rated Heating Capacity (at 47°F) - Mixed

N/A 47750 Btu/h

Standard Compliance

N/A UL

Casing Color

N/A Ivory White

Heat Exchanger

N/A Cross Fin Coil

Sound Pressure Level - Cooling

N/A 58 dBA

Sound Pressure Level - Heating

N/A 61 dBA

Sound Power Level - Cooling

N/A 76 dB

Sound Power Level - Heating

N/A 78 dB

Safety Devices

N/A High Pressure Switch, Fan Driver Overload Protector, Inverter Overload Protector, Fusible Plug, Fuse

Defrost Method

N/A Reverse Cycle Defrosting

Capacity Control

N/A 14 to 100 %

Standard Accessories

N/A Installation Manual, Operation Manual, Drain Socket, Clamps

Weight

N/A 80 kg176 lb

System Efficiency Metrics

System Performance EER2 Ducted

N/A 7.9

System Performance EER Ducted

N/A 7.9

System Performance EER2 Non-Ducted

N/A 10.3

System Performance EER Non-Ducted

N/A 10.3

System Performance EER Mixed

N/A 9.1

System Performance SEER2 Ducted

N/A 14.6

System Performance SEER Ducted

N/A 14.6

System Performance SEER2 Non-Ducted

N/A 20

System Performance SEER Non-Ducted

N/A 18.6

System Performance SEER Mixed

N/A 16.6

System Performance HSPF2 Ducted

N/A 8.3

System Performance HSPF Ducted

N/A 8.3

System Performance HSPF2 Non-Ducted

N/A 9.5

System Performance HSPF Non-Ducted

N/A 8.5

System Performance HSPF Mixed

N/A 8.4

COP (at 17°F) - Ducted

N/A 2.7

COP (at 17°F) - Non-Ducted

N/A 3

COP (at 17°F) - Mixed

N/A 2.85

COP (at 47°F) - Ducted

N/A 3.36

COP (at 47°F) - Non-Ducted

N/A 4.0

COP (at 47°F) - Mixed

N/A 3.68

Compressor

Type

N/A Hermetically Sealed Swing Type

Motor Output

N/A 3.0 kW

Starting Method

N/A Soft Start

Fan

Type

N/A Propeller Fan

Motor Output

N/A 0.200 kW

Airflow Rate

N/A 2682 scfm76 m³/min

Drive

N/A Direct Drive

Refrigerant

Refrigerant Name

N/A R410A

Charge

N/A 3.4 kg7.5 lb

Control

N/A Electronic Expansion Valve

Dimensions

Depth

N/A 12 5/8 in320 mm

Width

N/A 37 in940 mm

Height

N/A 39 in990 mm

Pipe Connections - Liquid

N/A 3/8 in9.5 mm

Pipe Connections - Gas

N/A 5/8 in15.9 mm

Maximum allowable length between OD and ID unit - Actual Piping Length

N/A 230 ft70 m

Maximum allowable length between OD and ID unit -Equivalent Piping Length

N/A 295 ft90 m

Maximum allowable length between OD and ID unit - Total Piping Length

N/A 984 ft300 m

Maximum allowable length after branch - Actual Piping Length

N/A 131 ft40 m

Maximum allowable height difference between OD and ID units - Difference in Height

N/A 98 ft30 m

Maximum allowable height difference between ID and ID units - Difference in Height

N/A 49 ft15 m

Features and Benefits

N/A Re-inventing residential air-conditioning by breaking technological barriers, the new Residential VRV brings inverter driven VRV to solve some of the age-old single-family HVAC challenges.

  • Available in 2, 3, 4 and 5 ton models
  • Superior zoning capabilities with 1 to 1 and 1 to multi connections
  • Broader diversity with ability to provide cooling and heating in up to 9 zones
  • Flexibility to choose heat pump or gas furnace or Duel-fuel heating capability
  • Auto and programmable modes for heat pump to gas heat switch over temperatures
  • Compatible with all the 12 types and 65 models of Daikin VRV indoor fan coil units and 80 - 97% AFUE Daikin communicating gas furnaces
  • Dependable heat pump operation in extreme ambient conditions down to -4°F in heating and up to 122°F in cooling
  • Year round comfort and energy savings delivered by combining VRV and VRT technologies
  • Quite operation with sound levels of under 58 dbA make for easy install close to Lot lines
  • Space saving compact design allows up to 75% reduction in install space
  • Reduced installation cost with re-use of existing refrigerant lines and uninsulated liquid line
  • Engineered with Daikin’s Swing compressor technology
  • Backed by best in class 10 year parts limited warranty and 10 years replacement compressor limited warranty