The Daikin DZ9VC heat pump offers a High-Efficiency, Inverter Driven Communicating, Split System Heat Pump.
Unit of Measure

Specifications

Maximal Cooling Capacity

N/A 46500 Btu/h

Maximal Heating Capacity

N/A 46000 Btu/h

Compressor Type

N/A Swing

Valve Connection Type

N/A Ball Valve

Voltage

N/A 208/230 V

Phase

N/A 1

Min/Max Volts

N/A 197/253 V

Frequency

N/A 60 Hz

System Efficiency Metrics

Up to SEER2

N/A 22.5

Up to HSPF2

N/A 8.2

Dimensions

Electrical Conduit Size

N/A 1/2 or 3/4 in

Depth

N/A 35 1/2 in

Width

N/A 35 1/2 in

Height

N/A 41 5/8 in

Liquid Line Size (O.D.)

N/A 3/8 in

Suction Line Size (O.D.)

N/A 1 1/8 in

Liquid Valve Size (O.D.)

N/A 3/8 in

Suction Valve Size (O.D.)

N/A 7/8 in

Features

N/A

Standard Features

  • Daikin variable speed swing and scroll compressors
  • High density foam compressor sound blanket
  • Compatible with Daikin One+ smart thermostat and other Daikin communicating equipment
  • Daikin control algorithmic logic
  • In communicating mode, only two lowvoltage wires to outdoor unit required
  • Diagnostic indicator lights, seven segment LED display, and fault code storage
  • Daikin Inside intelligence for diagnostics
  • Field selectable boost mode increases compressor speed during unusually high loads
  • Quiet DC outdoor fan motor
  • Fully charged for 15’ of tubing length
  • Field installed bi flow filter drier
  • Coil and ambient temperature sensors
  • Suction pressure transducer (in cooling mode)
  • Sweat connection service valves with easy access to gauge ports
  • AHRI Certified; ETL Listed

Cabinet Features

  • Removable grille-style top design compliant with UL 60335-2-40
  • Venturi for increased velocity of airflow Custom Nickel Gray powder-paint finish
  • 500-hour salt-spray tested
  • Wire fan discharge grille
  • Steel louver coil guard
  • Heavy-gauge galvanized-steel cabinet
  • Top and side maintenance access
  • Single-panel access to controls with space provided for field-installed accessories
  • When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)