Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.

CAD CART (0)
  • Cart is empty
Whole House Gas Furnace
  • Up to 80% AFUE
  • Dedicated downflow installation
  • Self-diagnostic control board continuously monitors the system for consistent reliable operation
  • Durable tubular stainless-steel heat exchanger
  • Quiet multi-speed motor
  • Quiet single-speed induced draft blower
  • Durable hot surface igniter
  • Heavy-gauge steel cabinet with durable baked-enamel finish
  • Fully insulated heat exchanger and blower section
  • Optional continuous air circulation to keep the air moving throughout the home
Unit of Measure
Items
dd80vc-rightquarter-case-downflow

DD80SS - Multi-Position, Multi-Speed Gas Furnaces 80% AFU

dd80vc-rightquarter-case-downflow

DD80SS - Multi-Position, Multi-Speed Gas Furnaces 80% AFU

dd80vc-rightquarter-case-downflow

DD80SS - Multi-Position, Multi-Speed Gas Furnaces 80% AFU

dd80vc-rightquarter-case-downflow

DD80SS - Multi-Position, Multi-Speed Gas Furnaces 80% AFU

dd80vc-rightquarter-case-downflow

DD80SS - Multi-Position, Multi-Speed Gas Furnaces 80% AFU
Variant N/A Natural Gas N/A Low NOx N/A Natural Gas N/A Low NOx N/A Natural Gas
Input Heating Capacity N/A 40000 Btu/h N/A 40000 Btu/h N/A 60000 Btu/h N/A 60000 Btu/h N/A 80000 Btu/h
Natural Gas Output N/A 32000 Btu/h N/A 32000 Btu/h N/A 48000 Btu/h N/A 48000 Btu/h N/A 64000 Btu/h
LP Gas Output N/A 32000 Btu/h N/A 32000 Btu/h N/A 48000 Btu/h N/A 48000 Btu/h N/A 64000 Btu/h
Annualized Fuel Utilization Efficiency (AFUE) N/A 80 %
Available AC N/A 3 A N/A 3 A N/A 3 A N/A 3 A N/A 4 A
Temperature Rise Range N/A 25 - 55 ºF N/A 25 - 55 ºF N/A 30 - 60 ºF N/A 30 - 60 ºF N/A 35 - 65 ºF
Circulator Blower - Size (D x W) N/A 10 x 6 N/A 10 x 6 N/A 10 x 6 N/A 10 x 6 N/A 10 x 8
Circulator Blower - Horsepower N/A 1/3 hp N/A 1/3 hp N/A 1/3 hp N/A 1/3 hp N/A 1/2 hp
Circulator Blower - RPM N/A 1075
Circulator Blower - Speed N/A 4
Circulator Blower - Vent Diameter N/A 4 in
Circulator Blower - No. of Burners N/A 2 N/A 2 N/A 3 N/A 3 N/A 4
Min. Circuit Ampacity N/A 4.8 A N/A 4.8 A N/A 4.8 A N/A 4.8 A N/A 8.8 A
Max. Overcurrent Device N/A 15 A
Shipping Weight N/A 88 lb N/A 88 lb N/A 92 lb N/A 92 lb N/A 105 lb
Depth N/A 28 1/2 in
Width N/A 14 in N/A 14 in N/A 14 in N/A 14 in N/A 17 1/2 in
Height N/A 33-1/2 in