Print Back
8 1/2 Ton Gas/Electric Direct Drive 3 Phase 575V
Unit of Measure

Specifications

Type

Light Commercial Packaged Gas/Electric

Cooling Capacity

97000 Btu/h8 1/2 T

IEER

14.8

EER

11.2

AHRI Reference #

210240226

Sound Level

82.6 dB

Operating Weight

1070 lb

Shipping Weight

1150 lb

Heating Capacity

Heating Capacity

180000 Btu/h

Heat Range

Medium

No. of Burners

6

High Stage Input

180 Btu/h

High Stage Output

145.8 Btu/h

Low Stage Input

135 Btu/h

Low Stage Output

109.4 Btu/h

Thermal Efficiency

81

High Stage Temperature Rise Range

25 to 55 ºF

Low Stage Temperature Rise Range

25 to 55 ºF

Evaporator Motor / Coil

Evaporator Motor Type

Direct Drive

External Static Pressure (ESP)

Standard

Wheel Dia. x Width

15 X 12 in

Indoor Nominal CFM

3230

RPM

300-1600

Evaporator Motor Horsepower

2.4 hp

Filter Size

20 x 20 x 2 (2) in20 x 25 x 2 (2) in

Drain Size (NPT)

3/4 in

R-410A Refrigerant Charge

71/68 oz

Evaporator Coil Face Area

13.4 ft²

Rows Deep

2

Fins per Inch

16

Condenser Fan / Coil

Quantity of Condenser Fan Motors

2

RPM (High/Low stage)

1050

Outdoor Horsepower

1/3 hp

Diameter

22 in

No. of Fan Blades

3

Condenser Coil Face Area

29.1 ft²

Rows Deep

1

Fins per Inch

23

Compressor

Quantity

2

Type

Scroll

Stage

1

Rated Load Amps

6 A

Locked Rotor Amps

41 A

Electrical Data

Voltage

575 V

Number of Phases

3

Frequency

60 Hz

Indoor Blower FLA

4.0 A

Max External Static

0.8 inWc

Outdoor Fan FLA

0.67 A

Min. Circuit Ampacity

18.9 A

Max. Overcurrent Protection

20 A

Power Supply Conduit Hole Diameter

1.375 in

Low-Voltage Conduit Hole Diameter

0.5 in

Dimensions

Depth

93-3/4 in

Width

60-3/8 in

Height

54 5/8 in

Features and Benefits

N/A Installation
Daikin Packaged units are designed with fast and easy installation in mind and are ideal for both new construction and retrofit projects. Our packaged rooftop units are built to be a direct replacement for most rooftop units on the field without the need of a curb adapter, to be able to replace the unit in a shorter time and at a lower cost (compared to the previous design).

Cabinet Construction
Daikin packaged rooftop units are made with high quality galvanized steel with a powder-paint finish to provide higher corrosion resistance.

Compressor
High performance, low noise scroll compressors to match the required total load.

Supply Fan
Indoor fan motors are direct drive EEM motors as standard to provide easy adjustment for airflow control.

Coils
All units use large face area outdoor coils. These coils are constructed with seamless copper tubes, mechanically bonded into aluminum plate-type fins with full drawn collars to completely cover the tubes for high operating efficiencies.

Controls and Wiring
Packaged rooftop units come equipped with a well-organized, large, easy to use weatherproof internal control box with easy access, for a better user experience.

Filtration
Unit provides a draw-through filter section as standard for better air quality and long lasting component maintenance.

Heating Section
Wide range of natural gas selections effectively handle most comfort heating demand from morning warm-up control to full heat, all available with Daikin’s Wrinkle Bend heat exchanger technology.

Electric Heat
Units are completely wired and tested at the factory to provide faster commissioning and start-up.