Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.

CAD CART (0)
  • Cart is empty
Whole House Packaged Gas/Electric
  • Heavy-duty stainless-steel heat exchanger
  • High-efficiency two-stage scroll compressor with factory-installed sound blanket
  • Variable-speed ECM indoor blower motor
  • Copper tube/aluminum fin evaporator coil (5 Ton)
  • All-aluminum evaporator coil (2-4 Ton)
  • Two-stage gas valve; natural gas with easy conversion to propane
  • Power-assisted combustion
  • All blower operation and all safety circuits complete with self-diagnostics
  • Loss-of-charge protection and high-pressure switch
  • Direct-spark ignition system with microprocessor-based control for the entire ignition sequence
  • For installation in California’s South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the SCAQMD Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
  • AHRI Certified; ETL Listed
  • Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant powder-paint finish
  • Aluminum foil-facing internal insulation reinforced with fiberglass scrim
  • Compressor sound blanket
  • Compressor grommets for vibration isolation
  • All models fit in a standard-size pick-up truck
  • Convenient access panels
  • Bottom 2" high base rails for easier handling
  • When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
Unit of Measure

Nominal Capacity

N/A 5.0 TR

Cooling Capacity

N/A 58500 Btu/h

Sensible Cooling Capacity

N/A 43500 Btu/h

System Performance SEER

N/A 16.0

System Performance EER

N/A 12.0

AHRI Reference

N/A 9134477

Heating Capacity Input

N/A 138000 Btu/h

Heating Capacity Output

N/A 112000 Btu/h

Heating Capacity Low-Fire Output

N/A 84000 Btu/h

Sound Level

N/A 78 dB

Annualized Fuel Utilization Efficiency (AFUE)

N/A 81 %

Temperature Rise Range

N/A 55 - 105 °F

No. of Burners

N/A 6

Orifice Size Natural

N/A 53 in

Orifice Size Propan

N/A 1.51 mm

Voltage

N/A 208 to 230 V

Phase

N/A 1

Frequency

N/A 60 Hz

Indoor Blower - Full Load Amps (FLA)

N/A 6.9 A

Outdoor Fan - Full Load Amps (FLA)

N/A 2.0 A

Outdoor Fan - Rated Load Amps (RLA)

N/A 4.4 A

Total Unit Amps

N/A 35.8 A

Min. Circuit Ampacity

N/A 42.5 A

Max. Overcurrent Protection

N/A 60 A

Shipping Weight

N/A 660 lb

Operating Weight

N/A 630 lb

Type

N/A ECM

Wheel (D x W)

N/A 11 x 10

Evaporator Motor Cooling

N/A 2000 ft³/min

Indoor Nominal

N/A T3 L / T4 H

Motor Amps (Cooling)

N/A 6.9 A

Horsepower

N/A 1 hp

RPM

N/A 1050

Face Area

N/A 8.9 ft²

Rows Deep

N/A 4

Fins per Inch

N/A 16

Piston Size (Cooling)

N/A TXV

Filter Size

N/A 8.9 ft²

Drain Size (NPT)

N/A 3/4 in

Refrigerant Charge

N/A 154 oz

Horsepower

N/A 1/3 hp

RPM

N/A 1095

Fan Diameter

N/A 22 in

Fan Blades

N/A 4

Outdoor Nominal

N/A 3800 ft³/min

Face Area

N/A 19.0 ft²

Rows Deep

N/A 2

Fins per Inch

N/A 27

Quantity

N/A 1

Type

N/A Scroll

Stage

N/A 2

Rated Load Amps (RLA)

N/A 26.9 A

Locked Rotor Amps (LRA)

N/A 152.9 A

Entrance Size Power Supply

N/A 1 1/8 in

Entrance Size Control Voltage

N/A 7/8 in

Depth

N/A 48 3/4 in

Width

N/A 74 1/2 in

Height

N/A 42 3/4 in

N/A

Standard Features

  • Durable, corrosion-resistant T-140 aluminized steel tubular heat exchanger
  • High-efficiency two-stage scroll compressor
  • Convertible airflow: horizontal or downflow application
  • Multi-speed ECM indoor blower motor
  • Copper tube/aluminum fin condenser coil
  • All-aluminum evaporator coil on 2- to 4-ton units
  • Aluminum-copper evaporator coil on 5-ton units
  • Power-assisted combustion
  • Loss-of-charge protection & high-pressure switch
  • AHRI Certified; ETL Listed
  • Two-stage gas valve; natural gas with easy conversion to propane with accessory kit
  • Direct spark ignition system includes a microprocessor- based control for the entire ignition sequence
  • All blower operation and all safety circuits complete with self-diagnostics
  • All models comply with California Low NOx emission standards

Cabinet Features

  • Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant powder-paint finish
  • Aluminum foil-facing internal insulation reinforced with fiberglass scrim
  • Convenient access panels
  • One roof curb fits 2-4 ton units
  • Bottom, 2” high base rails for easier handling
  • 2-4 ton models fit a standard-size pick-up truck
  • When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
  • Meets cabinet air leakage requirements when tested in accordance with ASHRAE standard 193

Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.