Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.

CAD CART (0)
  • Cart is empty
  • Heavy-duty stainless-steel heat exchanger
  • High-efficiency two-stage scroll compressor with factory-installed sound blanket
  • Variable -speed ECM indoor blower motor
  • Copper tube/aluminum fin evaporator coil (5 Ton)
  • All-aluminum evaporator coil (2-4 Ton)
  • Two-stage gas valve; natural gas with easy conversion to propane
  • Power-assisted combustion
  • All blower operation and all safety circuits complete with self-diagnostics
  • High and low-pressure switch protection
  • Direct-spark ignition system with microprocessor-based control for the entire ignition sequence
  • This furnace does not comply with the SCAQMD Rule 1111 nor the SJVAPCD Rule 4905 14 ng/J NOx emission limit and therefore is not eligible for installation in California’s South Coast Air Quality Management District (SCAQMD) nor the San Joaquin Valley Air Pollution Control District (SJVAPCD).
  • All models comply with California Low NOx standards.
  • AHRI Certified; ETL Listed
Unit of Measure

Nominal Capacity

N/A 5.0 T

Cooling Capacity

N/A 58000 Btu/h

Sensible Cooling Capacity

N/A 42600 Btu/h

System Performance SEER2

N/A 15.2

System Performance EER2

N/A 11.2

AHRI Reference

N/A 209319572

Heating Capacity Input

N/A 135000 Btu/h

Heating Capacity Output

N/A 1012550 Btu/h

Heating Capacity Low-Fire Output

N/A 84000 Btu/h

Sound Level

N/A 78 dB

Annualized Fuel Utilization Efficiency (AFUE)

N/A 81 %

Temperature Rise Range

N/A 55 - 105 °F

No. of Burners

N/A 6

Orifice Size Natural

N/A 53 in

Orifice Size Propan

N/A 1.51 mm

Voltage

N/A 208 to 230 V

Phase

N/A 1

Frequency

N/A 60 Hz

Indoor Blower - Full Load Amps (FLA)

N/A 6.9 A

Outdoor Fan - Full Load Amps (FLA)

N/A 2.8 A

Outdoor Fan - Rated Load Amps (RLA)

N/A 4.4 A

Total Unit Amps

N/A 35.8 A

Min. Circuit Ampacity

N/A 43.3 A

Max. Overcurrent Protection

N/A 70 A

Shipping Weight

N/A 655 lb

Operating Weight

N/A 630 lb

Type

N/A ECM

Wheel (D x W)

N/A 11 x 10

Evaporator Motor Cooling

N/A 2000 ft³/min

Indoor Nominal

N/A T3 L / T4 H

Motor Amps (Cooling)

N/A 6.9 A

Horsepower

N/A 1 hp

RPM

N/A 1050

Face Area

N/A 8.9 ft²

Rows Deep

N/A 4

Fins per Inch

N/A 16

Piston Size (Cooling)

N/A TXV

Filter Size

N/A 8.9 ft²

Drain Size (NPT)

N/A 3/4 in

Refrigerant Charge

N/A 150 oz

Horsepower

N/A 1/3 hp

RPM

N/A 1095

Fan Diameter

N/A 22 in

Fan Blades

N/A 4

Outdoor Nominal

N/A 3800 ft³/min

Face Area

N/A 19.0 ft²

Rows Deep

N/A 2

Fins per Inch

N/A 27

Quantity

N/A 1

Type

N/A Scroll

Stage

N/A 2

Rated Load Amps (RLA)

N/A 27 A

Locked Rotor Amps (LRA)

N/A 139.9 A

Entrance Size Power Supply

N/A 1 1/8 in

Entrance Size Control Voltage

N/A 7/8 in

Depth

N/A 73 3/8 in

Width

N/A 47 5/8 in

Height

N/A 43 1/2 in

N/A

Standard Features

  • Heavy-duty stainless-steel heat exchanger
  • High-efficiency two-stage scroll compressor with factory-installed sound blanket
  • Variable -speed ECM indoor blower motor
  • Copper tube/aluminum fin evaporator coil (5 Ton)
  • All-aluminum evaporator coil (2-4 Ton)
  • Two-stage gas valve; natural gas with easy conversion to propane
  • Power-assisted combustion
  • All blower operation and all safety circuits complete with self-diagnostics
  • High and low-pressure switch protection
  • Direct-spark ignition system with microprocessor-based control for the entire ignition sequence
  • This furnace does not comply with the SCAQMD Rule 1111 nor the SJVAPCD Rule 4905 14 ng/J NOx emission limit and therefore is not eligible for installation in California’s South Coast Air Quality Management District (SCAQMD) nor the San Joaquin Valley Air Pollution Control District (SJVAPCD).
  • All models comply with California Low NOx standards.
  • AHRI Certified; ETL Listed

Cabinet Features

  • Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant grey powder-paint finish (Sandstone Beige for the 5-ton model)
  • Aluminum foil-facing internal insulation reinforced with fiberglass scrim
  • Louvered condenser coil protection
  • Compressor sound blanket
  • Compressor grommets for vibration isolation
  • Horizontal or downflow application
  • Convenient access panels
  • Bottom 2" high base rails for easier handling
  • When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.