Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.
CAD CART (0)
▾
New Simple and Stylish design with expanded line up with single module units from 6-20T and dual-modules up to 40T Space-saving 16 - 20 T single module units provide up to 34% footprint and up to 500 lbs./unit weight reduction compared to previous series High energy efficiency with IEERs up to 28.5 delivers up to 30% efficiency increase Year-round comfort and energy saving with Daikin's Variable Refrigerant Temperature Technology (VRT) Heating down to -13°F as standard and high heating capacities at 17°F make it an ideal choice for all-electric heat pump solutions Hot gas defrost circuit allows for installation without base pan heater High dust moisture protection with an IP55 rated sealed E-box Dual-Fuel ready with connectivity to Daikin communicating gas furnace or all-electric heat pump heating for optimized operational cost based on utility rates Increased piping lengths of up to 361 ft. vertical separation between ODU and IDU provide additional application flexibility compared tomore previous VRV systems Design flexibility to enlarge system from single to a dual-module without changes to installed main pipe sizes for phased installation or tenant fit-out buildings Local code compliance-ready from factory via alignment with compliance needs, such as OSHPD Seismic, Miami Dade Wind, and Chicago Pressure relief code Reduced wiring costs with up to 27.4% reduction in MCA values compared to previous series Engineered for ease of installation and service with three-segment panel design Factory ships with increase space for easy field piping connection to service valves Built-in data recorder to store up to 40 minutes of operational data Integrates with new Daikin HERO ecosystem, an IoT -based remote monitoring and diagnostics platform. less
Unit of Measure
- Specifications
- Electrical Data
- Compressor
- Fan
- Refrigerant
- Dimensions
- Features
- System Efficiency Metrics
Nominal Cooling Capacity |
N/A 264000 Btu/h77.4 kW |
Rated Cooling Capacity |
N/A 252000 Btu/h73.9 kW |
Nominal Heating Capacity |
N/A 297000 Btu/h87.0 kW |
Rated Heating Capacity |
N/A 252000 Btu/h82.6 kW |
Power Supply |
N/A 3 phase, 60 Hz, 208/230 V |
Casing Color |
N/A Ivory White (5Y 7.5/1) |
Heat Exchanger |
N/A Cross Fin Coil |
Sound Pressure Level (Reference Date) |
N/A 67 dB |
Sound Power Level (Reference Data) |
N/A 88 dB |
Unit Combination |
N/A RXYQ120AATJB RXYQ144AATJB |
Safety Devices |
N/A High Pressure Switch, Fan Driver Overload Protector, Overcurrent Fuse, Inverter Overload Protector, Leak Detecting Device |
Defrost Method |
N/A Deicer |
Capacity Control |
N/A 1 to 100 % |
Standard Accessories |
N/A Installation Manual, Operation Manual, Connection Pipes, Clamps |
Weight |
N/A 683 + 750 lb310 + 340 kg |
Min/Max Volts |
N/A 187/253 V |
Min. Circuit Ampacity |
N/A 36.5 + 47.8 A |
Maximum Overcurrent Protection |
N/A 40 + 50 A |
Rated Load Amps |
N/A (10.5 + 10.8) + (10.0 + 15.8) A |
Outdoor Fan Motor - Rated Output |
N/A (0.65 x 2) x 2 kW(2.3 x 2) x 2 A |
Short-Circuit Current Rating |
N/A SCCR kA rms, Symmetrical 600 V MAX: 5 |
Type |
N/A Hermetically sealed scroll type |
Volume |
N/A ( 11.3 + 12.8 ) + ( 11.6 + 17.6 ) m³/h |
Number of Revolutions |
N/A ( 5340 + 6060 ) + ( 5496 + 5196 ) rpm |
Motor Output x Number of Units |
N/A ( 3.26 + 3.7 ) x 1 + ( 3.36 + 5.41 ) x 1 kW |
Starting Method |
N/A Soft Start |
Type |
N/A Propeller fan |
Motor Output |
N/A 0.65 x 2 + 0.65 x 2 kW |
Air Flow Rate |
N/A 8965 + 9935 ft³/min253.9 + 281.3 m³/min |
Fan Drive |
N/A Direct drive |
Refrigerant Name |
N/A R410A |
Refrigerant Charge |
N/A 25.4 + 25.8 lb11.5 + 11.7 kg |
Refrigerant Control |
N/A Electronic Expansion Valve |
Dimensions: (H x W x D) |
N/A 65-3/8 x 48-13/16 x 30-1/8 + 65-3/8 x 48-13/16 x 30-1/8 in1660 x 1240 x 765 + 1660 x 1240 x 765 mm |
Pipe Connections - Liquid |
N/A 3/4 in19.1 mm |
Pipe Connections - Suction Gas Pipe |
N/A 1-3/8 in34.9 mm |
N/A
|
System Performance EER Ducted |
N/A 10.1 |
System Performance EER Non-Ducted |
N/A 11 |
System Performance IEER Ducted |
N/A 18.2 |
System Performance IEER Non-Ducted |
N/A 21.6 |
System Performance Heating COP Ducted |
N/A 3.2 |
System Performance Heating COP Non-Ducted |
N/A 3.4 |
System Performance Heating COP 17F Ducted |
N/A 2.2 |
System Performance Heating COP 17F Non-Ducted |
N/A 2.2 |