Engineered with Daikin’s vapor injection compressor for greater heating performance at lower ambient temperatures.
- VRV with Variable Refrigerant Temperature (VRT)
- High heating capacity up to 100% of nominal at 0°F (-18°C), up to 85% of nominal at -13°F (-25°C), and up to 60% of nominal at -22°F (-30°C)
- Engineered with Daikin vapor injection compressor for optimized part load efficiencies
- Capacity range from 6 to 20 tons
- 208-230V / 3ph / 60Hz (RXLQ_TBTJA)
Model Type |
N/A Heat Pump |
Fan Type |
N/A Propellor Fan |
Heat Exchanger Type |
N/A Cross Fin Coil |
Color |
N/A Ivory White (5Y7.5/1) |
Voltage |
N/A 208-230 V |
Frequency |
N/A 60 Hz |
Cooling Capacity |
N/A 96000 Btu/h |
Heating Capacity |
N/A 108000 Btu/h31.7 kW |
Compressor Type |
N/A Hermetically Sealed Scroll |
Compressor Displacement |
N/A 17.7 m³/h |
Fan Air Flow Rate |
N/A 7989 ft³/min226 m³/min |
Safety Devices |
N/A High Pressure Switch, Fan Driver Overload Protector, Overcurrent Fuse, Inverter Overload Protector, Leak Detecting Device |
Weight |
N/A 360 kg793 lb |
Height |
N/A 66-11/16 in1694 mm |
Width |
N/A 48-7/8 in1242 mm |
Depth |
N/A 30-3/16 in767 mm |
Pipe Connections - Liquid |
N/A 3/8 in9.5 mm |
Pipe Connections - Suction Gas Pipe |
N/A 7/8 in22.2 mm |
Maximal Pipe Length (Total) |
N/A 540 ft |
Maximal Pipe Length (Vertical) |
N/A 295 ft |
System Performance EER Non-Ducted |
N/A 11 |
System Performance EER Ducted |
N/A 10.7 |
System Performance Heating COP 17F Ducted |
N/A 2.25 |
System Performance Heating COP 17F Non-Ducted |
N/A 2.25 |
System Performance Heating COP 47F Ducted |
N/A 3.3 |
System Performance Heating COP 47F Non-Ducted |
N/A 3.5 |
System Performance IEER Non-Ducted |
N/A 18.5 |
System Performance IEER Ducted |
N/A 16.7 |
N/A
|
N/A
|
Cooling Capacity Note |
N/A Indoor temp.: 80°FDB (26.7°CDB), 67°FWB (19.4°CWB) / Outdoor temp.: 95°FDB (35.0°CDB) / Equivalent piping length: 25 ft. (7.6 m), level difference: 0 ft. (0 m). |
Heating Capacity Note |
N/A Indoor temp.: 70°FDB (21.1°CDB) / Outdoor temp.: 47°FDB (8.3°CDB), 43°FWB (6.1°CWB) / Equivalent piping length: 25 ft. (7.6 m), level difference: 0 ft. (0 m) |
Sound Note |
N/A Anechoic chamber conversion value, measure under ISO standard conditions. During actual operation, these values are normally somewhat higher as a result of ambient, conditions. |