Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.
Engineered with Daikin’s vapor injection compressor for greater heating performance at lower ambient temperatures.
- VRV with Variable Refrigerant Temperature (VRT)
- High heating capacity up to 100% of nominal at 0°F (-18°C), up to 85% of nominal at -13°F (-25°C), and up to 60% of nominal at -22°F (-30°C)
- Engineered with Daikin vapor injection compressor for optimized part load efficiencies
- Capacity range from 6 to 20 tons
- 575V / 3ph / 60Hz (RXLQ_TBYCA)
Model Type |
N/A Heat Pump |
Fan Type |
N/A Propellor Fan |
Heat Exchanger Type |
N/A Cross Fin Coil |
Color |
N/A Ivory White (5Y7.5/1) |
Voltage |
N/A 575 V |
Frequency |
N/A 60 Hz |
Cooling Capacity |
N/A 96000 Btu/h |
Heating Capacity |
N/A 108000 Btu/h31.7 kW |
Compressor Type |
N/A Hermetically Sealed Scroll |
Compressor Displacement |
N/A 17.7 m³/h |
Fan Air Flow Rate |
N/A 7989 ft³/min226 m³/min |
Safety Devices |
N/A High Pressure Switch, Fan Driver Overload Protector, Overcurrent Fuse, Inverter Overload Protector, Leak Detecting Device |
Weight |
N/A 360 kg793 lb |
Height |
N/A 66-11/16 in1694 mm |
Width |
N/A 48-7/8 in1242 mm |
Depth |
N/A 30-3/16 in767 mm |
Pipe Connections - Liquid |
N/A 3/8 in9.5 mm |
Pipe Connections - Suction Gas Pipe |
N/A 7/8 in22.2 mm |
Maximal Pipe Length (Total) |
N/A 540 ft |
Maximal Pipe Length (Vertical) |
N/A 295 ft |
System Performance EER Non-Ducted |
N/A 11 |
System Performance EER Ducted |
N/A 10.7 |
System Performance Heating COP 17F Ducted |
N/A 2.25 |
System Performance Heating COP 17F Non-Ducted |
N/A 2.25 |
System Performance Heating COP 47F Ducted |
N/A 3.3 |
System Performance Heating COP 47F Non-Ducted |
N/A 3.5 |
System Performance IEER Non-Ducted |
N/A 18.5 |
System Performance IEER Ducted |
N/A 16.7 |
N/A
|
N/A
|
Cooling Capacity Note |
N/A Indoor temp.: 80°FDB (26.7°CDB), 67°FWB (19.4°CWB) / Outdoor temp.: 95°FDB (35.0°CDB) / Equivalent piping length: 25 ft. (7.6 m), level difference: 0 ft. (0 m). |
Heating Capacity Note |
N/A Indoor temp.: 70°FDB (21.1°CDB) / Outdoor temp.: 47°FDB (8.3°CDB), 43°FWB (6.1°CWB) / Equivalent piping length: 25 ft. (7.6 m), level difference: 0 ft. (0 m) |
Sound Note |
N/A Anechoic chamber conversion value, measure under ISO standard conditions. During actual operation, these values are normally somewhat higher as a result of ambient, conditions. |
Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.