Daikin’s VRV IV systems integrate advanced technology to provide comfort control to help maximize energy efficiency and reliability. VRV IV provides a solution for multi-family residential to large commercial applications desiring heating or cooling. The VRV IV is the first variable refrigerant flow (VRF) system to be assembled in North America.
Items |
REYQ72TTJU-obsolete VRV-IV Heat Recovery Outdoor Units - REYQ Series (Obsolete) |
REYQ96TTJU-obsolete VRV-IV Heat Recovery Outdoor Units - REYQ Series (Obsolete) |
REYQ120TTJU-obsolete VRV-IV Heat Recovery Outdoor Units - REYQ Series (Obsolete) |
REYQ144TTJU-obsolete VRV-IV Heat Recovery Outdoor Units - REYQ Series (Obsolete) |
REYQ168TTJU-obsolete VRV-IV Heat Recovery Outdoor Units - REYQ Series (Obsolete) |
|||||
Model Type | N/A Heat Recovery | |||||||||
Fan Type | N/A Propellor Fan | |||||||||
Heat Exchanger Type | N/A Cross Fin Coil with Ultra Gold Corrosion Resistant Fin Coating | |||||||||
Color | N/A Ivory White (5Y7.5/1) | |||||||||
Voltage | N/A 208/230 V | |||||||||
Phase | N/A 3 | |||||||||
Frequency | N/A 60 Hz | |||||||||
Cooling Capacity | N/A 72000 Btu/h | N/A 96000 Btu/h | N/A 120000 Btu/h | N/A 144000 Btu/h | N/A 168000 Btu/h | |||||
Heating Capacity | N/A 81000 Btu/h23.7 kW | N/A 108000 Btu/h31.7 kW | N/A 135000 Btu/h39.6 kW | N/A 162000 Btu/h47.5 kW | N/A 188000 Btu/h55.1 kW | |||||
Height | N/A 66-11/16 in1694 mm | |||||||||
Width | N/A 36-11/16 in932 mm | N/A 48-7/8 in1242 mm | N/A 48-7/8 in1242 mm | N/A 48-7/8 in1242 mm | N/A 48-7/8 in1242 mm | |||||
Depth | N/A 30-3/16 in767 mm | |||||||||
Heat Exchanger Salt Spray Rating | N/A 1000 Hours, Blister Rating 10 (ASTM B117) | |||||||||
Compressor Type | N/A Hermetically Sealed Scroll | |||||||||
Compressor Displacement | N/A 11.5 m³/h | N/A 7.7 + 7.7 m³/h | N/A 9.5 + 9.5 m³/h | N/A 9.4 + 14.1 m³/h | N/A 11.0 + 16.5 m³/h | |||||
Compressor Number of Revolutions | N/A 3600 rpm | N/A 3630, 3630 rpm | N/A 4470, 4470 rpm | N/A 4440, 4440 rpm | N/A 5190, 5190 rpm | |||||
Compressor Motor Output x Number of Units | N/A 3.8 x 1 kW | N/A (2.2 + 2.2 ) x 1 kW | N/A (2.7 + 2.7 ) x 1 kW | N/A (2.7 + 4.6) x 1 kW | N/A (3.2 + 5.4) x 1 kW | |||||
Compressor Starting Method | N/A Soft Start | |||||||||
Fan Motor Output | N/A 0.4 x 1 kW | N/A 0.35 x 2 kW | N/A 0.35 x 2 kW | N/A 0.8 x 2 kW | N/A 0.8 x 2 kW | |||||
Fan Air Flow Rate | N/A 5544 ft³/min157 m³/min | N/A 5827 ft³/min165 m³/min | N/A 6286 ft³/min178 m³/min | N/A 8228 ft³/min233 m³/min | N/A 8228 ft³/min233 m³/min | |||||
Pipe Connections - Gas | N/A 19.1 mm | N/A 22.2 mm | N/A 28.6 mm | N/A 28.6 mm | N/A 28.6 mm | |||||
Pipe Connections - High/Low Pressure Gas | N/A 5/8 in15.9 mm | N/A 3/4 in19.1 mm | N/A 3/4 in19.1 mm | N/A 7/8 in22.2 mm | N/A 7/8 in22.2 mm | |||||
Power Supply | N/A 208/230 V, 60 Hz, 3 phase | |||||||||
Refrigerant Name | N/A R410A | |||||||||
Refrigerant Charge | N/A 21.9 lb9.9 kg | N/A 25.8 lb11.7 kg | N/A 25.8 lb11.7 kg | N/A 25.8 lb11.7 kg | N/A 25.8 lb11.7 kg | |||||
Safety Devices | N/A High Pressure Switch, Fan Driver Overload Protector, Overcurrent Relay, Inverter Overload Protector | |||||||||
Defrost Method | N/A Deicer | |||||||||
Capacity Control | N/A 15 to 100 % | N/A 11 to 100 % | N/A 10.0 to 100 % | N/A 10.0 to 100 % | N/A 10.0 to 100 % | |||||
System Performance IEER Ducted | N/A 21.1 | N/A 24.3 | N/A 22.6 | N/A 22.2 | N/A 20.80 | |||||
System Performance SCHE Ducted | N/A 22.60 | N/A 23 | N/A 25.1 | N/A 23.8 | N/A 22.80 | |||||
System Performance Heating COP Ducted | N/A 3.8 | N/A 3.7 | N/A 3.5 | N/A 3.6 | N/A 3.3 | |||||
System Performance Heating COP 17F Ducted | N/A 2.6 | N/A 2.3 | N/A 2.3 | N/A 2.4 | N/A 2.20 | |||||
Weight | N/A 230 kg507 lb | N/A 319 kg703 lb | N/A 319 kg703 lb | N/A 354 kg780 lb | N/A 354 kg780 lb | |||||
|