Print Back
Unit of Measure

Specifications

Variant

N/A Low NOx

High Fire Input

N/A 100000 Btu/h

High Fire Output - Natural Gas

N/A 80000 Btu/h

High Fire Output - LP Gas

N/A 80000 Btu/h

Low Fire Input

N/A 70000 Btu/h

Low Fire Output - Natural Gas

N/A 56000 Btu/h

Low Fire Output - LP Gas

N/A 56000 Btu/h

Maximum CFM

N/A 2000 ft³/min

Annualized Fuel Utilization Efficiency

N/A 80 %

Available AC

N/A 2.0 to 5.0 A

Temperature Rise Range

N/A 25 - 55 ºF

Min. Circuit Ampacity

N/A 15.32 A

Max. Overcurrent Device

N/A 20 A

Shipping Weight

N/A 124 lb

Circulator Blower

Side (D x W)

N/A 10 x 10

Horsepower

N/A 1 hp

Speed

N/A 9

Vent Diameter

N/A 4 in

No. of Burners

N/A 5

Dimensions

Depth

N/A 28 in

Width

N/A 21 in

Height

N/A 33-1/2 in

Features

N/A Standard Features

  • Heavy-duty stainless-steel dual-diameter, tubular heat exchanger
  • Two-stage gas valve provides quiet, economical heating
  • Durable Silicon Nitride igniter
  • Quiet two-speed draft inducer
  • Self-diagnostic control board
  • Efficient and quiet multi-speed airflow system
  • Multiple continuous fan speed options offer quiet air circulation
  • California Low NOx emissions-compliant models available
  • Can no longer be installed in California’s South Coast Air Quality Management District (SCAQMD) on or after October 1,2021.
  • AHRI Certified; ETL Listed
Cabinet Features
  • Multi-position installation:
    DM80TN: Upflow, horizontal left or right.
    DC80TN: Downflow, horizontal left or right.
    Convenient left or right connection for gas and electrical service
  • Cabinet air leakage (QLeak) ≤ 2%
  • Heavy-gauge steel cabinet with durable baked-enamel finish
  • Fully insulated heat exchanger and blower section

Notes

N/A

  • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
  • Gas Service Connection 1/2” FPT
  • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.