Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.
Daikin Packaged units are designed with an easier and faster installation in mind for both new construction and retrofit. Built for comfort cooling applications in normal heating, ventilating, and air conditioning. Designed on a variety of fuels such AC only, Gas Electric and Heat Pump to fit on most types of applications, at different static and efficiency requirements.
Capacity range from 6, 7.5-12.5 tons features:
- Heat exchanger with wrinkle bend tech
- Belt Drive flexibility
- Two stage capacity for partial load
- Specifications
- Evaporator Motor / Coil
- Condenser Fan / Coil
- Compressor
- Electrical Data
- Dimensions
- Features
Model Type |
N/A Gas/Electric Unit |
Nominal Heating Capacity |
N/A 70000 Btu/h |
Cooling Capacity |
N/A 46500 Btu/h4 TR |
System Performance EER |
N/A 11.5 |
System Performance IEER |
N/A 14.0 |
Heat Range |
N/A Low |
No. of Burners |
N/A 3 |
High Stage Input |
N/A 70.0 Btu/h |
High Stage Output |
N/A 56.0 Btu/h |
Low Stage Input |
N/A 52.5 Btu/h |
Low Stage Output |
N/A 42.0 Btu/h |
Thermal Efficiency (T.E.) |
N/A 80 |
High Stage Temperature Rise Range |
N/A 20 to 50 ºF |
Low Stage Temperature Rise Range |
N/A 15 to 45 ºF |
Operating Weight |
N/A 631 lb |
Shipping Weight |
N/A 677 lb |
Motor Type |
N/A Belt Drive |
External Static Pressure (ESP) |
N/A Standard |
Wheel Dia. x Width |
N/A 12 x 10 in |
Indoor Nominal CFM |
N/A 1470 |
Evaporator Motor - RPM |
N/A 1725 |
Evaporator Motor Horsepower |
N/A 1.0 hp |
Filter Size |
N/A 20 x 25 x 2 (2) in |
Drain Size (NPT) |
N/A 3/4 in |
R410A Refrigerant Charge |
N/A 108 oz |
Evaporator Coil - Face Area |
N/A 6.4 ft² |
Evaporator Coil - Rows Deep |
N/A 4 |
Evaporator Coil - Fins per Inch |
N/A 16 |
Quantity of Condenser Fan Motors |
N/A 1 |
RPM (High/Low stage) |
N/A 1075 |
Outdoor Horsepower |
N/A 1/4 hp |
Diameter |
N/A 22 in |
No. of Fan Blades |
N/A 4 |
Condenser Coil Face Area |
N/A 13.3 ft² |
Rows Deep |
N/A 2 |
Fins per Inch |
N/A 28 |
Quantity |
N/A 1 |
Type |
N/A Scroll |
Stage |
N/A 1 |
Rated Load Amps |
N/A 13.1 A |
Locked Rotor Amps |
N/A 83.1 A |
Voltage |
N/A 208-230 V |
Number of Phases |
N/A 3 |
Frequency |
N/A 60 Hz |
Indoor Blower FLA |
N/A 3.4 A |
Max External Static |
N/A 0.7 inWc |
Outdoor Fan FLA |
N/A 1.4 A |
Min. Circuit Ampacity |
N/A 21.2/21.2 A |
Max. Overcurrent Protection |
N/A 30/30 A |
Power Supply Conduit Hole Diameter |
N/A 1.125 in |
Low-Voltage Conduit Hole Diameter |
N/A 0.5 in |
Depth |
N/A 74 in |
Width |
N/A 48-5/16 in |
Height |
N/A 39-7/8 in |
N/A
|
Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws.